BAC Baltimore Balticare GmbH
BAC Balticare S3000E cooling tower
S3000E features:
cross-flow, axial fan, induced draft principle
Ultra-quiet design
- A choice of low-noise axial fans and whisper-quiet fans for minimal ambient noise
- BACross filling guides the water calmly and without water splashing noises to the pool.
- Try our XES3000E range with smaller motors for extremely low noise levels.
- Factory engineered, tested and dimensioned sound attenuation is available at the air intake to further reduce operating noise.
Unprecedented energy savings
- Evaporative cooling for system-wide energy savings at lower operating temperatures.
- Axial fans require half the energy of similar centrifugal fan units.
- Save pump kW! Less pump head for this gravity water distribution system. During periods of reduced load, weir dams partially close the hot water basin, saving pump energy .
- BACross fill - factory configured for maximum water/air contact and low airside pressure drop for optimal cooling tower efficiency with limited energy consumption.
- Highly efficient fan motors
- XES3000E series with smaller motors to reduce power consumption with the same cooling capacity.
Low maintenance and hassle free inspection
- The S3000E has a spacious service channel (inside) providing easy access for safe inspection and maintenance of the unit's internal components. Unprecedented comfort when standing inside.
- Equip the unit with a ladder and platform for quick and safe access to all unit components.
- Access via large hinged door to internal walkway : no need to drain a basin to inspect the interior of the unit or the fill pack.
- You can easily inspect and clean the core of the BACross fill sheet by sheet without disassembling. BACross construction reduces fouling. Optional telescopic supports for easy blade replacement.
- The fill includes integral drift eliminators tested and certified by Eurovent.
- Inspection of the water distribution (hot water basin and nozzles) outside the unit, possible during operation .
- Optional water distribution tray covers prevent debris from accumulating inside the unit.
- Self-cleaning cold water basin and fill above sloping basin to flush out dirt and debris.
- Fans are easily accessible from inside and outside.
- Optional cleanout port helps remove silt and sludge from cooling tower basin.
- Suction strainer with removable anti-turbulence hood.
- Optional sump suction prevents accumulation of sediment in the cold water basin.
- Various corrosion -resistant materials, for example the unique Baltibond hybrid coating , for guaranteed long service life.
Unprecedented hygiene control
- Easy-to-clean and easy-to-inspect S3000E towers reduce hygiene risks due to bacteria (e.g. Legionella) or biofilm inside.
- Self-cleaning cold water basin and fill above sloping basin to flush out dirt and debris.
- BACross fill for reduced fouling and easy cleaning sheet by sheet without disassembly.
- The fill includes integral drift eliminators tested and certified by Eurovent.
- Combined air intake shields block sunlight to prevent biological growth inside the tower, filter the air and prevent water from splashing outside.
- Optional water distribution tray covers prevent debris from accumulating inside the unit.
- Optional cleanout port helps remove silt and sludge from cooling tower basin.
- Optional sump suction prevents accumulation of sediment in the cold water basin.
Reliable operation all year round
- Excellent rated thermal performance - meets all flow and temperature requirements.
- The thermal performance of the S3000E cooling towers is tested and certified by Eurovent.
- Patented BACross packing with maximum air/water contact offers unbeatable heat transfer performance.
- Various corrosion -resistant materials, for example the unique Baltibond hybrid coating and GKF housing walls for guaranteed long service life.
- Optional drive system for more efficiency and less maintenance.
S3000E properties
Cross flow, axial fan, induced draft principle
power range
18 - 285 l/s
water distribution
Gravity, with variable flow weirs
Maximum water inlet temperature
55 °C standard packing 60 °C with alternative packing
Typical applications
- Medium to large air conditioning and industrial applications
- Replacement of site-built towers
overview
- working principle
- design features
- options and accessories
- Technical specifications