BAC Baltimore Balticare GmbH

BAC Balticare S3000E cooling tower

S3000E features: cross-flow, axial fan, induced draft principle

Ultra-quiet design

  • A choice of low-noise axial fans and  whisper-quiet fans  for minimal ambient noise 
  • BACross filling  guides the water calmly and  without water splashing noises to the pool.
  • Try our XES3000E range with smaller motors for extremely low noise levels.
  • Factory engineered, tested and dimensioned  sound attenuation  is available at the air intake to further reduce operating noise.

Unprecedented energy savings

  • Evaporative cooling  for system-wide energy savings at lower operating temperatures.
  • Axial fans  require  half the energy of  similar centrifugal fan units.
  • Save pump kW!  Less pump head for this gravity water distribution system. During periods of reduced load,  weir dams  partially close the hot water  basin, saving pump energy .
  • BACross fill  - factory configured for maximum water/air contact and low airside pressure drop for optimal cooling tower efficiency with limited energy consumption.
  • Highly efficient fan motors
  • XES3000E  series with smaller motors to reduce power consumption with the same cooling capacity.

Low maintenance and hassle free inspection

  • The S3000E has a  spacious service  channel (inside) providing  easy access  for safe inspection and maintenance of the unit's internal components. Unprecedented comfort when standing  inside.
  • Equip the unit with  a ladder and platform  for quick and safe access to all unit components.
  • Access via large hinged door to internal walkway : no need to drain a basin to inspect the interior of the unit or the fill pack.
  • You can easily inspect and clean the core of the  BACross fill sheet by sheet without disassembling.  BACross construction reduces fouling. Optional  telescopic supports  for easy blade replacement. 
  • The fill includes integral  drift eliminators tested and certified by Eurovent.
  • Inspection of the  water distribution  (hot water basin and nozzles) outside the unit,  possible during operation  .
  • Optional  water distribution tray covers  prevent debris from accumulating inside the unit.
  • Self-cleaning cold water basin and fill above sloping  basin  to flush out dirt and debris.
  • Fans  are easily accessible from inside and outside.
  • Optional cleanout  port  helps remove  silt and sludge from cooling tower basin.
  • Suction  strainer with removable anti-turbulence hood.
  • Optional  sump suction  prevents accumulation of sediment in the cold water basin. 
  • Various corrosion  -resistant materials, for example the unique Baltibond hybrid coating , for guaranteed long service life.

Unprecedented hygiene control

  • Easy-to-clean and easy-to-inspect S3000E towers  reduce  hygiene risks due to bacteria (e.g. Legionella) or biofilm inside.
  • Self-cleaning cold water basin and fill above sloping  basin  to flush out dirt and debris.
  • BACross fill  for reduced fouling and easy cleaning sheet by sheet without disassembly.
  • The fill includes integral  drift eliminators tested and certified by Eurovent.
  • Combined air intake shields  block sunlight to prevent biological growth inside the tower, filter the air and prevent water from splashing outside.
  • Optional  water distribution tray covers  prevent debris from accumulating inside the unit.
  • Optional cleanout  port  helps remove  silt and sludge from cooling tower basin.
  • Optional  sump suction  prevents accumulation of sediment in the cold water basin. 

Reliable operation all year round

  • Excellent rated thermal performance - meets  all flow and temperature requirements.
  • The thermal performance of the S3000E cooling towers is tested and  certified by Eurovent.
  • Patented  BACross packing with  maximum air/water contact offers unbeatable heat transfer performance.
  • Various  corrosion -resistant  materials, for example the unique  Baltibond hybrid coating  and GKF housing walls for guaranteed long service life.
  • Optional  drive system  for more efficiency and less maintenance.

S3000E properties

Cross flow, axial fan, induced draft principle

power range

18 - 285 l/s

water distribution

Gravity, with variable flow weirs

Maximum water inlet temperature

55 °C standard packing 60 °C with alternative packing

Typical applications

  • Medium to large air conditioning and industrial applications
  • Replacement of site-built towers

 

overview

  • working principle
  • design features
  • options and accessories
  • Technical specifications