DIN EN 378 – Guidelines for Refrigeration Systems and Heat Pumps

The EU standard governs the safety, operation, and environmental impact of refrigeration systems and heat pumps.

DIN EN 378 is a key standard for refrigeration systems and heat pumps, setting requirements for safety, operation, and environmental considerations. It comprises four parts and establishes regulations for installation locations and the maximum permissible refrigerant charge, taking into account refrigerant classification.

 

Structure and Content of the Standard

DIN EN 378 is divided into four parts:

  • Basic Requirements, Definitions, Classification, and Selection Criteria
  • Design, Construction, Testing, Marking, and Documentation
  • Location and Protection of Persons
  • Operation, Maintenance, Repair, and Recovery

This structure ensures a comprehensive consideration of all relevant aspects of refrigeration systems and heat pumps.

 

Classification and Limits

A central element of DIN EN 378 is the classification of refrigerants and the determination of limits for their permissible charge sizes. The standard evaluates refrigerants based on their toxicity and flammability, assigning a maximum allowable charge for each.

Additionally, it provides guidance on the classification of access categories and installation locations to better assess potential risks and implement appropriate safety measures.

 

Practical Application

In practice, applying the standard requires careful planning and analysis. First, the refrigerant classification and charge limits defined in the standard must be reviewed. Then, the volume of the intended installation space and its intended use must be determined.

Based on this data, the maximum allowable refrigerant charge for the specific installation is calculated.

 

Requirements for System Operators

Operators and technicians of refrigeration systems are required to adhere to the standard’s provisions both when designing new systems and operating existing ones. This means that refrigerant classifications and charge limits must already be considered during the design phase.

Existing systems should be regularly inspected to ensure compliance with the current standards. In particular, in areas with human occupancy, alternative risk mitigation strategies must be considered to maintain the highest safety standards.

 

Conclusion

DIN EN 378 provides a comprehensive framework for the safe and efficient operation of refrigeration systems and heat pumps. It is essential to emphasize that each refrigeration system must be evaluated individually. The specific characteristics of the refrigerant used, the spatial conditions of the installation site, and the system's intended use require a careful, case-by-case assessment.

Only through such individual consideration can safety be ensured. System operators should use the standard as a guide for best practices while also taking into account the specific requirements of their operations and applicable local regulations.

Contents
Jobs
Mounting
Mechanic/Welder (m/f/d) at GEA
We are looking for three mechanics/welders (m/f/d) at our Berlin location.
GEA Refrigeration Germany GmbH
Ber­lin, Ger­ma­ny
Fulltime
Project management refrigeration technology
Commercial Employee Order Processing in Engineering (m/f/d)
To strengthen our team, we are looking for a commercial employee to handle engineering projects as soon as possible.
MTA Deutschland GmbH
Net­te­tal, Ger­ma­ny
Fitter refrigeration technology
MTA Refrigeration Technician (m/f/d) in Customer Service for Baden-Württemberg
To strengthen our team for the Stuttgart region, we are looking for you as a Refrigeration Technician (m/f/d) for our customer service.
MTA Deutschland GmbH
Net­te­tal, Ger­ma­ny
Fulltime

Get in Touch with the Author

If you have any questions or would like additional information, the author of this article is happy to assist you. Simply use the options below to get in touch directly.