GEA AWP Safety Relief Valves SVA
Safety Relief Valves SVA
AWP safety valves are suitable for installation as relief or overflow valves in the refrigerant cycles of industrial refrigeration systems. Safety valves are safety devices for protecting the refrigeration systems and their components from excess pressure (see also EN 378 part 2). They comply with AD2000 regulations. AWP safety valves open up to the valve lift stop if the start-to-leak pressure (set pressure) rises within the 10% range. They close if the pressure drops to the 10% range below the set point. AWP safety valves are maintenance-free. Any defects that occur in the functional performance of the valves can be repaired.
Technical features:
- Available in steel or stainless steel
- Selection of body material as per German DIN EN12284, AD2000 Series W
- Working media: glycol-based cold brine refrigerant EN 378 p. 1, e.g. NH3, R134a, R290 (propane), R507, blends with refrigerator oil, neutral, gas and liquid media, glycol-based cold brine
- Mounting position: vertical as per AD2000-leaflet A2, and horizontal
Safety Relief Valves SVA
Design angle type
Material steel or stainless steel
Nominal Size DN 15/25-65/65
Nominal pressure Level PS 25, PS 40, PS 63
Temperature Range A: -60 °C to +180 °CB: -50 °C to +110 °C
Connection flanged ends DIN, ANSI
screw ends
Set Pressure 4-63 bar